NameLocationTypeExcitation sourcesDetectorsIncubator / CO2Objective LensesSoftwareNotes
Zeiss LSM800 Confocal2.4Inverted, confocal405, 488, 561, 640 nm; 7-colour LED2x GaAsP PMT,Ìý sCMOS cameraStage top incubator,
°ä°¿2Ìý
10x 0.45 Air
20x 0.8 Air
40x 1.3 Oil
63x 1.4 Oil
Zen Blue 2.6Correlative Array Tomography (CAT) module
Zeiss Axio Scan.Z12.3Slide scanner, widefieldBright field; HXP 120 lampsCMOS cameraNo5x 0.25 Air
10x 0.45 Air
20x 0.8 Air
40x 0.95 Air
Zen Blue 3.1100 slide automated imaging
Zeiss Celldiscoverer 7Ìýwith Airyscan 2 confocal2.4Inverted, widefield, confocalBright field; 405, 488, 561, 640 nm; 7-colour LEDsCMOS camera,Ìý2xÌý PMT,Ìý Airyscan 2Yes + robot automation with separate incubator5x 0.35 Air
20x 0.7 Air
20x 0.95 Air
50x 1.2 Water
Additional 0.5x /2x magnification for all objectivesÌý
Zen Blue 3.5

Unattended long-term high-resolution imaging

IncuCyte S3

2.3

TC room

Inverted, widefieldGreen / Red LEDsCMOS cameraYes4x Air
10x Air
20x Air
IncuCyteUnattended long-term cell monitoring
EVOS XL CoreTC roomsInverted, widefieldBright fieldNoneNo4x Air
10x Air
20x Air
NoneCan be placed in TC hood for colony picking etc
Zeiss Axioscope 51.2Upright, widefieldBright field; 4-colour LEDsColour cameraNo

5x 0.16 Air
10x 0.3 Air
20x 0.5 Air
40x 0.75 AirÌý
63x 1.25 Oil
100x 1.3 Oil

NoneÌý
Zeiss Axio Vert.A1

2.3

TC room

Inverted, widefieldBright field; 2-colour LEDsMonochrome cameraNo5x 0.15 Air
10x 0.25 Air
20x 0.35 Air
40x 0.55 AirÌý
Zen BlueÌý
Zeiss LSM980 Confocal with Airyscan 2Ìý

2.3

QSH 413

Inverted, confocal405, 445, 488, 514, 561, 639nm;Ìý4-colour LEDs2xÌý PMT, 32x GaAsP array, Airyscan 2Yes, CO22.5x 0.1 Air
10x 0.45 Air
20x 0.8 Air
40x 1.3 Oil
63x 1.4 Oil
Zen Blue 3.58 Y Airyscan for 8 line parallel Airyscan imaging
Leica Stellaris 8 tauSTED / FLIM confocal2.3 (office)Inverted, confocal405, 440-790nm White Light Laser, 592 + 775nm STED4x Hybrid HyD detectorsYes, CO22.5x 0.07 Air
20x 0.75 Air
20x 0.75 Multi-immersion
40x 1.3 Oil
93x 1.3 Glycerol
100x 1.4 Oil
LASX 4

tauSTED for low power STED of live cells

FLIM lifetime imaging

Leica Mica Microhub2.3 (office)Inverted, confocal, widefield

LED (Widefield):Ìý365,Ìý 470, 555, 625 nm

Lasers (confocal):Ìý405,ÌýÌý488, 561, 638 nm

4x Camera (Widefield)

4x Hybrid HyD detectors (confocal)

Yes, CO210x 0.32 Air
20x 0.75 Air
63x 1.2 Water
63x 1.4 Oil
LASX 4

4 colour simultaneous imaging

THUNDER / LIGHTNING computational clearing / deconvolution

Cairn Spinning Disk confocal / TIRF / LiveSRQSH 3Inverted, confocalÌý(spinning disk)

LED (confocal):Ìý405, 445, 470, 520, 530, 555, 640 nm

Lasers (TIRF):Ìý405,ÌýÌý488, 561, 638 nm

2x sCMOS cameraYes, CO210x 0.45 Air
20x 0.8 Air
40x 1.3 Oil
60x 1.2 Water
60x 1.4 Oil
100x 1.49 Oil
VisiView

2 camera simultaneous imaging

FRAP Photobleaching

PALM /ÌýSTORM super-resolution

Perkin Elmer Opera Phenix2.3Inverted, confocal (spinning disk)Lasers:Ìý405,ÌýÌý488, 561, 640 nm4x sCMOS cameraYes, CO25x 0.16 Air
10x 0.3 Air
20x 1.0 Water
40x 1.1 Water
63x 1.15 Water
Harmony4 colour simultaneous imaging